Skip to main content

Put A Number On The Campus Repair Backlog

We assess campus buildings system by system, add up the repair backlog, and turn it into a ranked capital plan your board can follow. It’s the same method we use for any group of buildings, delivered by our team.

Campus buildings build up a specific kind of debt: systems kept in service past their replacement date, a backlog that outgrows the capital budget, and condition data too old to rest a request on.

Who It’s For
Vice presidents of facilities, campus planners, budget officers and capital planning staff.
Deadlines This Work Serves
Capital requests, board budget meetings and accreditation self-studies.
Where We Are
Smyrna, Georgia, working across the Southeast.

What You’re Up Against

Why Campus Renewal Keeps Slipping

  1. The Backlog Outgrows The Budget

    Repairs put off this year cost more next year. Without one number for the backlog, it’s hard to show the board how fast it is growing.

  2. Renewal Loses To New Buildings

    A new building has a donor and a ribbon cutting. A roof replacement has neither, so renewal requests need stronger evidence to win.

  3. What You Know Lives In People

    Building history sits in old reports, work orders and the memory of staff close to retiring. When they leave, the record leaves with them.

What We Deliver

The Evidence Behind Your Next Capital Request

Each engagement is scoped to land before the meeting or filing that needs it. We usually recommend starting with condition and following it with the plan.

  • Condition, remaining life and cost to repair for every system in your academic buildings, residence halls and support facilities, with one Facility Condition Index (FCI) score per building.

    Lands Before

    A capital request, or an accreditation self-study

  • A ranked 10-year capital plan with its scoring printed in the plan, so renewal projects compete on the same terms as everything else.

    Lands Before

    The board’s budget meeting

  • For property held outside the core campus: whether each one is worth more to the institution held, improved or sold.

    Lands Before

    A board decision on a property

What A Portfolio View Looks Like

Every Building On One Screen, Colored By Condition

The example is a fictional county portfolio, not a campus. The method doesn’t change with the building: rate each system, add up what it would cost to fix, and compare buildings side by side. Roof color shows each building’s FCI band. FCI is its repair backlog divided by what it would cost to replace.

The Portfolio At A Glance

2 healthy, under 5%3 watch, 5%–10%3 critical, over 10%Height shows floor area

Main Library

Built 1974 · 62,000 sq ft · 4 floors

Facility Condition Index (FCI)12.2%Critical

Fund first

Roof

Condition 2 of 10 · 1 yr left · $1.3M to renew

Every building on one model: height shows floor area, and roof color shows its Facility Condition Index band. Select a building to see what to fund first. Illustrative data — a fictional county portfolio, not a client.

Then Every System, Building By Building

Each row is a building and each column a system, scored from 1 (failing) to 10 (like new). The few that need money first stand out before anyone reads a number.

Every Building, Every System

BuildingRoofWalls & windowsHeating/coolingElectricalPlumbingElevatorsFire protectionControlsFinishesSiteFCI
Main LibraryBuilt 1974Roof: condition 2 of 10, 1 yr leftExterior walls & windows: condition 5 of 10, 14 yrs leftHeating & cooling: condition 3 of 10, 1 yr leftElectrical: condition 5 of 10, 9 yrs leftPlumbing: condition 6 of 10, 12 yrs leftConveying (elevators): condition 5 of 10, 6 yrs leftFire protection: condition 6 of 10, 11 yrs leftBuilding controls: condition 4 of 10, 4 yrs leftFinishes, partitions & ceilings: condition 5 of 10, 5 yrs leftSite, paving & drainage: condition 6 of 10, 8 yrs left12.2%
Eastside Branch LibraryBuilt 1998Roof: condition 7 of 10, 9 yrs leftExterior walls & windows: condition 8 of 10, 24 yrs leftHeating & cooling: condition 6 of 10, 8 yrs leftElectrical: condition 7 of 10, 18 yrs leftPlumbing: condition 8 of 10, 22 yrs leftConveying (elevators): condition 7 of 10, 12 yrs leftFire protection: condition 8 of 10, 20 yrs leftBuilding controls: condition 4 of 10, 1 yr leftFinishes, partitions & ceilings: condition 6 of 10, 6 yrs leftSite, paving & drainage: condition 7 of 10, 10 yrs left3.0%
Fire Station 3Built 1988Roof: condition 6 of 10, 7 yrs leftExterior walls & windows: condition 7 of 10, 20 yrs leftHeating & cooling: condition 3 of 10, 2 yrs leftElectrical: condition 6 of 10, 12 yrs leftPlumbing: condition 6 of 10, 14 yrs leftConveying (elevators): condition 6 of 10, 9 yrs leftFire protection: condition 7 of 10, 15 yrs leftBuilding controls: condition 5 of 10, 5 yrs leftFinishes, partitions & ceilings: condition 6 of 10, 6 yrs leftSite, paving & drainage: condition 6 of 10, 9 yrs left7.2%
Public Works YardBuilt 1969Roof: condition 3 of 10, 1 yr leftExterior walls & windows: condition 3 of 10, 4 yrs leftHeating & cooling: condition 5 of 10, 6 yrs leftElectrical: condition 2 of 10, 2 yrs leftPlumbing: condition 5 of 10, 9 yrs leftConveying (elevators): condition 4 of 10, 5 yrs leftFire protection: condition 5 of 10, 8 yrs leftBuilding controls: condition 4 of 10, 3 yrs leftFinishes, partitions & ceilings: condition 5 of 10, 4 yrs leftSite, paving & drainage: condition 4 of 10, 4 yrs left11.3%
Civic CenterBuilt 1982Roof: condition 3 of 10, 2 yrs leftExterior walls & windows: condition 6 of 10, 18 yrs leftHeating & cooling: condition 5 of 10, 6 yrs leftElectrical: condition 6 of 10, 12 yrs leftPlumbing: condition 6 of 10, 15 yrs leftConveying (elevators): condition 5 of 10, 7 yrs leftFire protection: condition 3 of 10, 3 yrs leftBuilding controls: condition 5 of 10, 5 yrs leftFinishes, partitions & ceilings: condition 6 of 10, 7 yrs leftSite, paving & drainage: condition 6 of 10, 10 yrs left6.0%
Riverside Community CenterBuilt 2006Roof: condition 8 of 10, 12 yrs leftExterior walls & windows: condition 8 of 10, 30 yrs leftHeating & cooling: condition 7 of 10, 11 yrs leftElectrical: condition 8 of 10, 22 yrs leftPlumbing: condition 8 of 10, 28 yrs leftConveying (elevators): condition 8 of 10, 15 yrs leftFire protection: condition 8 of 10, 24 yrs leftBuilding controls: condition 7 of 10, 7 yrs leftFinishes, partitions & ceilings: condition 7 of 10, 8 yrs leftSite, paving & drainage: condition 7 of 10, 13 yrs left0.0%
Parks Maintenance ShopBuilt 1979Roof: condition 5 of 10, 6 yrs leftExterior walls & windows: condition 5 of 10, 12 yrs leftHeating & cooling: condition 2 of 10, 1 yr leftElectrical: condition 5 of 10, 8 yrs leftPlumbing: condition 5 of 10, 10 yrs leftConveying (elevators): condition 5 of 10, 6 yrs leftFire protection: condition 5 of 10, 9 yrs leftBuilding controls: condition 4 of 10, 3 yrs leftFinishes, partitions & ceilings: condition 3 of 10, 2 yrs leftSite, paving & drainage: condition 5 of 10, 6 yrs left12.6%
Courthouse Parking DeckBuilt 1991Roof: condition 6 of 10, 8 yrs leftExterior walls & windows: condition 6 of 10, 16 yrs leftHeating & cooling: condition 6 of 10, 9 yrs leftElectrical: condition 3 of 10, 2 yrs leftPlumbing: condition 6 of 10, 13 yrs leftConveying (elevators): condition 3 of 10, 1 yr leftFire protection: condition 2 of 10, 2 yrs leftBuilding controls: condition 5 of 10, 4 yrs leftFinishes, partitions & ceilings: condition 6 of 10, 8 yrs leftSite, paving & drainage: condition 5 of 10, 5 yrs left5.5%
1 failing10 like new

Orange: 3 or lower, poor condition

Scroll sideways for every system.

Each building's systems on one screen, colored by condition score from 1 (failing) to 10 (like new); the last column is each building's Facility Condition Index (FCI). Illustrative data — a fictional county portfolio, not a client.

How To Buy

Buying From Us Through Your Normal Process

Contact us for our capability statement
Solicitations
We respond to requests for qualifications (RFQs) and requests for proposals (RFPs).
Documents
Capability statement, W-9 and certificate of insurance available on request.
Pricing
By scope: how many buildings, which engagements, and how complete your records are. Set out in the proposal.
Office
Portfoliq is headquartered at 2310 Goodwood Blvd SE, Smyrna, GA 30080, and works with owners and public agencies across the Southeast.

Questions We Hear

What We’re Asked Before A First Call

Does your method work for academic buildings and residence halls?

Yes. Each building is rated system by system, from the roof to heating and cooling to electrical, the same way whatever it houses. The building’s use changes the costs, not the method.

Can you work from our last facility condition assessment?

Yes. We carry earlier ratings forward with their original report and date, and update the systems that have changed. Where a building has no usable record, we scope a field assessment with you.

Do you lead campus master plans?

No. We supply the condition and cost data a master planning team works from: what each building needs, what it will cost, and how soon.

How long does it take, and how is it priced?

A condition assessment typically takes about 12 weeks, depending on how many buildings and how complete your records are. Pricing is by scope; contact us for a scoped proposal.

Tell Us When Your Capital Request Is Due

A building list and the date your board needs the request is enough to start. We’ll outline what can be ready by then.

Contact Us